The Bissell PowerSteamer Pro Deluxe is a household cleaning appliance used to deep clean dirt and allergens from carpet fibers and hardwood floors, and it features a patented PowerBrush to loosen soiled areas. If your PowerSteamer's brush is unable to turn while the appliance is in use, the pump belt probably is broken, which prevents the appliance from rotating the brush during the cleaning process. Both the pump belt and brush belt are replaceable in the machine without professional service, as the PowerSteamer Pro Deluxe includes a belt access door for manual replacement.
Instructions
-
-
1
Press the power switch to the "off" position on the back of the Bissell cleaner.
-
2
Disconnect the Bissell power cord from the electric outlet, and insert the blade of the screwdriver into the belt access door. The belt access door is located on the right side of the vacuum facing you.
-
-
3
Pry off the access door, and lift it off of the vacuum's base to access the belts.
-
4
Pull the broken belts slowly out of the belt access compartment to remove them. The pump belt loops around the vacuum's motor shaft and becomes twisted in the vacuum when the belt is broken.