The R7184b1032 is an interrupted electric-oil primary control manufactured by Honeywell. R7184 series primary controls can be found in oil-fired furnaces and boilers from a variety of manufacturers, including Nordyne and New Yorker. The controls have a restricted lockout safety feature that shuts off the oil heater when flame is detected during the valve-on delay -- or if it isn't detected during the trial for ignition. You can unlock a Honeywell R7184b1032 oil-heater primary control in less than a minute.
Instructions
-
-
1
Watch the LED on the primary control to confirm it's in restricted lockout mode; if the control is locked out, the light will flash on and off every half second.
-
2
Locate the red "Reset" button on the side of the primary control. Press and hold the button for 30 seconds, or until the LED flashes twice.
-
-
3
Look at the LED; a single, one-second flash indicates that the control was unlocked successfully and has returned to Standby mode.