Turn off the circuit or remove the fuse that connects to the Trane XE60 furnace/air conditioner.
Disconnect the wiring to the old motor using a pliers. The motor is located in the bottom section of the XE60. Untwist the twist caps if necessary, or cut the existing wires using a wire cutter. Remove the motor. A GE1375 rpm 1/2 hp motor is standard in the XE60.
Install the replacement motor. Secure it by attaching the bolts, using a pliers.
Attach a capacitor to the brown striped wire on the new XE60 motor using solder and a soldering iron, then solder a solid brown wire to the remaining free end of the capacitor. Twist together a length of jumper wire from the brown striped wire to the common wire to feed it to the motor.
Secure the wire connections with plastic caps or using straight crimp connectors. Follow these color matches: blue-purple on the Trane XE60, red to red, green to chassis/ground.
Yellow and black wires are not used.