Measure the full width and length of the proposed driveway area.
Divide the overall driveway width dimension by the rebar grid spacing to determine the number of crossing bars required. Typical rebar grids use #3 (3/8-inch) rebar spaced between 18 and 24 inches apart. Add an additional crossing bar for each end of the driveway grid.
Multiply the number of crossing bars calculated in the previous step times the driveway's width minus 12 inches to determine the total linear quantity of rebar needed for the crossing bars. The deduction from the width will allow a standard 6-inch gap on each side between the ends of the rebar and the edge of the driveway concrete.
Divide the overall driveway length dimension by the rebar grid spacing to determine the number of crossing bars required. Add an additional bar for each side of the grid.
Multiply the number of lengthwise bars calculated in the previous step times the driveway's length minus 12 inches to determine the total linear quantity of rebar needed for the lengthwise bars. As with the crossing bars, the deduction from the length will allow a 6-inch gap on each end of the grid between the ends of the rebar and the edge of the driveway concrete.
Add the total linear quantities determined in steps 3 and 5 together, then divide the total by 20 to define the number of standard 20-foot lengths of rebar needed for your driveway project.